raid planner

What you actually get, and what it costs you to rebuild

Usable capacity in both TB and TiB, how many failures the array survives, how long a resilver takes, and the odds of hitting an unrecoverable read error while it runs. That last number is the one that kills arrays.

usable capacity
86.4 TB
78.6 TiB as the OS reports it · at 80% fill
raw purchased
144.0 TB
25% lost to redundancy
drive failures survived
2
rebuild time
2.1 days
at 100 MB/s sustained
URE risk per rebuild
57.9%
reads 108.0 TB to resilver
cost per usable TB
—
set a drive price
RAIDZ2 (ZFS)

The homelab default. Two-drive tolerance plus scrubbing.

how this is calculated

Usable capacity is data drives × capacity × your fill target. Vendors sell decimal terabytes (1012 bytes); your OS reports TiB (240). That is a 9% haircut before redundancy, and it is why a "20TB" drive shows up as 18.2TiB.

URE risk is 1 − e−bits/rate, where bits is everything the array must read to resilver one failed drive. A consumer drive rated 1 in 1014 is roughly one error per 12.5TB read — which is why wide RAID 5 arrays of large consumer drives are a coin flip during rebuild. Enterprise nearline is rated 1015, an order of magnitude better.

Rebuild time assumes sustained sequential throughput. A pool serving live traffic will be considerably slower, and slower rebuilds mean a longer window in which a second failure takes everything.

intellectual property